QA.TXT: QUALITY ASSURANCE ANCILLARY DATA FILE This file contains quality assurance parameters for the survey image. 1 2 3 4 5 6 7 1234567890123456789012345678901234567890123456789012345678901234567890123456 Data Take ID: 62.22 Site Name: Altai, China Site ID: G82 Product Type: Survey Image Carrier Frequency (GHz): 1.254 Polarization Channel: HH Number of Q/A Intervals: 3 Bit Error Rate, PRF-C (exp): 0.0 Number of Flywheels: 0 Turn-On Recv Only Noise Power (dBmW): 0.0 Turn-Off Recv Only Noise Power (dBmW): 0.0 Turn-On Ambiguity Resolution Probability: 0.00 Turn-Off Ambiguity Resolution Probability: 0.00 Survey fd Error (Hz): 0.0 Q/A Interval Data: Interval 1 Mean of Raw Data Histogram: 127.9 Standard Deviation of Raw Data Histogram: 23.1 % Over Saturation in Raw Data Histogram: 0.0 % Under Saturation in Raw Data Histogram: 0.0 Range Offset in Frequency Domain (MHz): 1.71 Signal-to-Noise Ratio (dB): 7.77 Spurious Peak Count: 3 DWP for Echo Monitor Plot (micro sec): 0.00 Caltone Gain (dBmW): -99.84 Caltone Phase (deg): 180.00 Mean of Image Histogram: Near Range: 61.66 Center Swath: 103.72 Far Range: 74.64 Standard Deviation of Image Histogram: Near Range: 43.89 Center Swath: 56.81 Far Range: 44.15 % Over Saturation in Image Histogram: Near Range: 0.00 Center Swath: 0.02 Far Range: 0.00 % Under Saturation in Image Histogram: Near Range: 0.00 Center Swath: 0.00 Far Range: 0.00 Interval 2 Mean of Raw Data Histogram: 127.9 Standard Deviation of Raw Data Histogram: 9.5 % Over Saturation in Raw Data Histogram: 0.0 % Under Saturation in Raw Data Histogram: 0.0 Range Offset in Frequency Domain (MHz): 1.71 Signal-to-Noise Ratio (dB): -7.57 Spurious Peak Count: 3 DWP for Echo Monitor Plot (micro sec): 0.00 Caltone Gain (dBmW): -98.21 Caltone Phase (deg): 180.00 Mean of Image Histogram: Near Range: 54.91 Center Swath: 45.05 Far Range: 56.09 Standard Deviation of Image Histogram: Near Range: 39.91 Center Swath: 31.30 Far Range: 36.89 % Over Saturation in Image Histogram: Near Range: 0.01 Center Swath: 0.00 Far Range: 0.01 % Under Saturation in Image Histogram: Near Range: 0.04 Center Swath: 0.00 Far Range: 0.01 Interval 3 Mean of Raw Data Histogram: 127.9 Standard Deviation of Raw Data Histogram: 11.2 % Over Saturation in Raw Data Histogram: 0.0 % Under Saturation in Raw Data Histogram: 0.0 Range Offset in Frequency Domain (MHz): 1.71 Signal-to-Noise Ratio (dB): -1.91 Spurious Peak Count: 3 DWP for Echo Monitor Plot (micro sec): 0.00 Caltone Gain (dBmW): -99.67 Caltone Phase (deg): 180.00 Mean of Image Histogram: Near Range: 30.15 Center Swath: 82.13 Far Range: 99.59 Standard Deviation of Image Histogram: Near Range: 12.36 Center Swath: 48.11 Far Range: 64.02 % Over Saturation in Image Histogram: Near Range: 0.00 Center Swath: 0.02 Far Range: 0.05 % Under Saturation in Image Histogram: Near Range: 0.04 Center Swath: 0.00 Far Range: 0.01